GUIDE

How the container number check digit works (ISO 6346).

4 min read · Updated 4 November 2026

Every shipping container number ends in a check digit. It's calculated from the other ten characters, so if one character is mistyped, the check digit almost always stops matching. It's the fastest way to catch a typo before it reaches the bill of lading.

How a container number is built

A container number has 11 characters, for example MSKU 123456 5:

  • 3 letters: the owner code, registered with the BIC
  • 1 letter: the equipment category (U for freight containers, J for detachable equipment, Z for trailers and chassis)
  • 6 digits: the serial number
  • 1 digit: the check digit

How the check digit is calculated

Each letter is turned into a number: A is 10, B is 12, and so on up to Z, skipping 11, 22 and 33. Digits keep their own value.

Each of the first ten values is multiplied by 2 raised to its position (1, 2, 4, 8 … 512). The results are added up, the total is divided by 11, and the remainder is the check digit. A remainder of 10 counts as 0.

What the check digit catches, and what it doesn't

It catches almost every single-character typo and most swapped neighbours, which are the usual mistakes when re-typing from a PDF.

It doesn't tell you the container is the right one for this booking. A valid number can still belong to a different shipment, so also compare container numbers across the SI, the VGM and the booking.

Free tools for this

Questions

Can I check a container number for free?
Yes. Use the free container number checker on this site: type the number and it shows the correct check digit.
Why does a remainder of 10 become 0?
The check digit has to be a single digit, so ISO 6346 maps 10 to 0. Owners usually avoid serial numbers that produce 10 for this reason.